SRP-147

SRP-147

Model: SRP-147

Starting at: $317.00

Description

The SRP-147 meter is designed for measuring of typical current or voltage signals. As a main advantage, this device is equipped with a large, 38 mm high LED display. Thanks to wide range of characteristic curves (linear, square root, quadratic, user-defined and volume characteristic for cylindrical tanks) the meters may be used in various process control systems. The 24V DC / 100 mA output is designed to supply measuring transducers, and the RS-485 port enables data transmission in production process monitoring systems. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. Moreover, the meter can be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter can be configured with the local keyboard or free S-Config software via the RS-485 communication port.

Specifications

Number of inputs

1

Input type

current (mA)

voltage (V)

voltage (mV)

Input range

0/4...20 mA

0/1...5V, 0/2...10V

0...60 mV, 0...75 mV, 0...100 mV, 0...150 mV

Output type

depends on configuration:

relay I=1A, U=30V DC/250V AC (cosø=1)

Open Collector: I=30 mA, U=30V DC, P=100 mW

0/4...20 mA: active current, operating range 0...24 mA max., load resistance 700 Ω max., resolution 13 bit

4...20 mA: passive current, isolated, operating range 2,8...24 mA max., load resistance 600 Ω@24VDC, resolution 13 bit

0/1...5V, 0/2...10V: active voltage, operating range 0...11V max., load resistance min. 2000 Ω, resolution 13 bit

Power supply

16...35V AC, 19...50V DC

85..260V AC/DC

11,4...15V AC/DC

Display

LED, 4 x 38 mm, red

LED, 4 x 38 mm, green

Communication Interface

RS-485 / Modbus RTU

Transmission parameters

1200...115200 bit/s, 8N1 / 8N2

Operating temperature

0...+50°C

-20…+50°C

Protection class

IP 20 (case and connection clips)

IP 65 (front)

optional integrated frame for panel cut-out sealing

Case material

NORYL-GFN2S E1

Mounting

panel

Case dimensions

144 x 72 x 100 mm

For more information on the SRP-147 please click the links below:

DATASHEET

MANUAL FOR mA OR V INPUT VERSION

MANUAL FOR mV INPUT VERSION

**To order this product please select an option from each of the categories below





Quick buy with PayPal