SUR-49B

SUR-49B

Model: SUR-49B

Starting at: $251.00

Description

The SUR-49B meter is equipped with one universal input, type:  0/4-20 mA, 0-10V, 0-150 mV, Pt 100/500/1000 or TC (K, S, J, T, N, R, B, E). During the measurement process only one kind of input is available. Temperature of cold ends is compensated automatically. RTD and TC inputs feature with fully linearized characteristics. Thanks to wide range of characteristic curves (linear, square root, quadratic, user-defined and volume characteristic for cylindrical tanks) the meters may be used in various process control systems. The 24V DC output is designed to supply measuring transducers, and the RS-485 port enables data transmission in production process monitoring systems. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. Moreover, the meter can be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter can be configured with the local keyboard or free S-Config software via the RS-485

Specifications

Number of inputs

1

Input type

universal

Input range

0/4...20 mA

0...60 mV, 0...75 mV, 0...100 mV, 0...150 mV

0/1...5V, 0/2...10V

0...300Ω, 0...3kΩ

Pt100, Pt500, Pt1000: -100...+600°C

TC K: -200...+1370°C, S: -50...+1768°C, J: -210...+1200°C, T: -200...+400°C, N: -200...+1300°C, R: -50...+1768°C, B: +250...+1820°C, E: -200...+1000°C

Output type

depends on configuration:

relay 5A/250V AC (resistance)

relay 3A/250V AC (reactance)

Open Collector: I=30 mA, U=30V DC, P=100 mW

0/4...20 mA: active current, operating range 0...24 mA max., load resistance 700 Ω max., resolution 13 bit

4...20 mA: passive current, isolated, operating range 2,8...24 mA max., load resistance 600 Ω@24VDC, resolution 13 bit

0/1...5V, 0/2...10V: active voltage, operating range 0...11V max., load resistance min. 2000 Ω, resolution 13 bit

Power supply

16...35V AC, 19...50V DC

85..260V AC/DC

11,4...15V AC/DC

Display

LED, 4 x 9 mm, red

20-points bargraph, red-green

Communication Interface

RS-485 / Modbus RTU

Transmission parameters

1200...115200 bit/s, 8N1 / 8N2

Operating temperature

0...+50°C

-20…+50°C

Protection class

IP 20 (case and connection clips)

IP 65 (front)

optional integrated frame for panel cut-out sealing

Case material

NORYL-GFN2S E1

Mounting

panel

Case dimensions

48 x 96 x 100 mm

For more information on the SUR-49B please click the links below:

DATASHEET

MANUAL

**To order this product please select an option from each of the categories below






Quick buy with PayPal