W&T 57713 Web-Thermo-Hygrobarometer

W&T 57713 Web-Thermo-Hygrobarometer

Model: 57713

$410.00

Measure, log and report...

The Web-Thermo-Hygrobarometer is an instrument that measures temperatures, relative humidity and air pressure and makes the values available in the network. The device includes an integrated data logger and numerous Web and network services for manual querying of the measurements or provides autonomous sending of messages.

 

Sensor:

  • Temperature sensor:
    • Measure range: -40°C...85°C
  • Relative humidity sensor:
    • Measuring range 0..100% RH, permissible ambient: 0..95% (non-condensing)
  • Air pressure sensor:
    • Measuring range 10-1100 hPa

Connectivity:

  • Intuitive Web interface for simpler configuration
  • Monitor temperatures and trends from a browser
  • Alarm and reporting function:
    • E-mail for alarm or reporting functions
    • SNMP polling / alarm traps
    • Configure up to 12 alarm messages
  • Dynamic integration into other Web sites:
    • Direct access to current measurement values, e.g. JavaScript (AJAX).
  • Current industry 4.0 protocols:
    • OPC UA, REST and MQTT support
  • Additional software interfaces for incorporating into your systems/databases:
    • SNMPv1, SNMPv2c, SNMPv3
    • Modbus-TCP
    • OPC UA, OPC DA
    • Syslog
    • Sensobase (database integration via ODBC)
    • TCP and UDP sockets, client and server
    • FTP (data logging)
  • Possible applications:
    • Monitor temperatures in the server room, network cabinet or office
    • Logging of measurements via FTP, Excel file, email attachment and internal memory
    • dew point measurement, climate monitoring
    • Green IT: Monitor efficiency of the server room climate control

Data logger:

  • Internal data logger
    • Memory size: min. 7 weeks, max. 20 years
    • Save frequency: 15, 30 sec, 1, 5, 15, 60 min
  • Document measurement data online in the W&T Cloud and access from anywhere in the world
  • Internal clock
    • Time synchronization via time server calibration
    • Battery-backed device clock

Standards & more

  • optional: ISO factory calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified documentation of the measured value deviations
    • Valid for 12 months
  • optional: DAkkS/DKD calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified traceability to national standards
    • Valid for 12 months
  • Supply voltage via Power-over-Ethernet (PoE)
    • Phantom power using data pairs
    • Power over unused wire pairs
    • External power supply is an alternative
  • Conforms to standards both in office and industrial environments:
    • High noise resistance per EN 61000-6-2
    • Low noise emission per EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3

 

Connections and displays:

  • Combined sensor:
    • Temperature, relative humidity and air pressure measurement
    • DB9 receptacle
    • Cable length: 2m (can be extended to max. 20m)
  • Network:
  • Galvanic isolation:
    • Network connection min. 1500 V
  • Power supply:
    • Power-over-Ethernet (PoE) or
    • DC 12V .. 48V (+/-10%) or
    • AC 18Veff .. 30Veff (+/-10%)
  • Supply connection:
    • Plug-in screw terminal, 5.08mm spacing
    • Labeled "L+" and "M"
  • Current consumption:
    • PoE Class 1 (0.44 - 3.84W)
    • typ. 62mA @24VDC, 80mA @20VAC,
    • max. 70mA @24VDC, 40mA @48VDC
  • Displays:
    • 1 LED Power
    • 2 LEDs Network Status
    • 4 LEDs Status and Error

Measuring unit:

  • Measuring range:
    • -40°C...85°C, 0..100% rF, 10-1100 hPa
  • Resolution:
    • 1/10 °C, 1/10% rF, 0.1 hPa
  • Display variables:
    • °Celsius, °Fahrenheit, °Kelvin,
      %relative humidity, abs. humidity g/m³, dew point °C,
      barometric pressure mBar, hPa,
      mixing ratio g/kg, enthalpy kJ/kg

  • Measuring error:

    • Temperature:
    • typ. @ 25°C ±0.3°C
    • max. @ -40..85°C ±1.5°C

    • Relative humidity:
    • typ. @ -20..60°C (normal range) ±1.8%rH (10-90%rH)
    • max. @ -20..60°C (normal range) ±4%rH (0-100%rH)
    • temporary @ -40..85°C (max range) +3%rH after 60h of operation
    • outside normal range
    • Long-term stability typ. <0.5%rH / year

    • Atmospheric pressure:
    • typ. @ 25°C ±0.8hPa (750..1100hPa)
    • max. @ 25°C ±2.5hPa (750..1100hPa)
    • max. @ -40..85°C: ±3.5hPa (300..1100hPa)
    • Long-term stability: typ. -1hPa / year
  • Measuring frequency:
    • 4s
  • Storage frequency:
    • 15s, 30s, 1m, 5m, 15m, 60m
  • Memory depth (4MB):
    • min. 7 weeks, max. 20 years

Housing and other data:

  • Housing:
    • Plastic compact housing for top-hat rail mount
    • 105x22x75mm (LxWxH)
  • Enclosure rating:
    • IP20
  • Weight:
    • approx. 200g
  • Ambient temperature:
    • Storage: -40..+70°C
    • Operating: Non-contiguous mounting: 0 .. +60°C
    • contiguous mounting: 0 .. +50°C
  • Permissible relative humidity:
    • 0..95% RH (non-condensing)
  • Scope of delivery:
    • 1x Web-Thermo-Hygrobarometer
    • 1x W&T sensor, 2m (temperature, relative humidity and barometric pressure)
    • 1x Quick Guide



5 year guarantee

Click here for manual: Link

For more information, please click below for the WuT webpage

Quick buy with PayPal